Ventilator controls

Mastering Ventilator controls

Date: November 29, 2023 | Posted by: Vikram Aditya Tirthani

Ventilators, with their intricate settings and controls, are lifelines in critical care, providing essential respiratory support to patients. Understanding these parameters is crucial for healthcare professionals to tailor treatment plans effectively. In this guide, we’ll explore the key ventilation settings and controls, shedding light on their significance in optimizing patient care.

Oxygen (O2%): The volume percentage of oxygen in the mixed gas delivered to the patient. It allows you to set the concentration of oxygen delivered to the patient, typically expressed as a percentage (e.g., 21% for room air, or 100% for pure oxygen).

Tidal Volume (Tv): The gas volume the patient inspires or expires each time during resting breathing. It determines the amount of air delivered in one breath.

Respiratory Rate (f): The number of mechanically controlled breaths delivered per minute to the patient. For an adult, a typical rate is 12-20 breaths per minute.

Inspiratory Time (Tinsp): Inspiratory time defines the duration of the inspiratory phase in one breathing cycle.

Positive End-Expiratory Pressure (PEEP): PEEP maintains positive pressure in the airways at the end of expiration to prevent alveolar collapse.

Inspiratory Hold / Pause Time (Tpause): This parameter controls the percentage of duration of Inspiratory phase, for which the gas delivery is paused, within the inspiratory phase itself.

Assist: Assist controls is used to turn On or OFF the assist trigger. When assist trigger is on, the patient’s spontaneous efforts are identified at the end of expiration, and a mechanical ventilation is triggered.

Flow Trigger: Flow trigger sensitivity specifies the flow rate needed to initiate a breath. To enable flow trigger it is essential to have a base flow at the late stage of expiration the ventilator delivers a base flow from the inspiratory limb to the expiratory limb.

Sigh: Sigh settings enable periodic deep breaths, enhancing lung recruitment.  Interval, Cycles and PEEP.

Flow Pattern: Flow pattern controls the shape of the inspiratory flow waveform, such as square or decelerating flow patterns.

Inspiratory Pressure (Pinsp): Inspiratory pressure controls the level of pressure applied during the inspiratory phase above the PEEP.

Ramp / Pressure Rise Time (Tslope): The ramp setting defines the time taken to reach the desired inspiratory pressure.

Pressure Support (Psupp): Pressure support defines the level of pressure assistance provided above PEEP during inspiration in pressure control breaths.

Expiratory Trigger Sensitivity (Exp): This sets the flow level required to detect the end of inspiration and initiate expiration. The ventilator is switched to the expiratory phase when the inspiratory flow drops to peak flow*Exp%.

Apnea Ventilation: Configures ventilation during apnea events, ensuring continuous support in the absence of spontaneous breaths.

Inspiratory to Expiratory Ratio (I:E): I:E ratio configures the ratio of inspiratory time to expiratory time.

Flow Control (Flow): Flow control regulates the rate at which gas is delivered during O2 Therapy mode, ensuring it matches the patient’s needs.

Apnea Vent – Tidal Volume (Tvapnea): Specifies the tidal volume delivered during apnea ventilation.

Minute Volume Percentage (MV%): MV% determines the percentage of the minute volume support, helping in fine-tuning ventilation based on the patient’s condition.

Navigating ventilation settings and controls is an intricate yet vital aspect of critical care. Healthcare professionals, armed with a deep understanding of these parameters, can provide tailored respiratory support, optimizing patient outcomes. As technology evolves, staying informed about the latest advancements in ventilator settings ensures healthcare providers can harness the full potential of these life-saving devices.

Need Support?

Get in touch with us using our contact form.

scrolltop