Next Generation Smart Ventilators
with a perfect combination of
Performance | Precision | Safety
Graphical representation of important lung parameters for assess the lung condition at a glance, for quick and efficient decision making.
Smart ventilation enables clinicians to set the desired percentage of minute volume support and ventilator takes care of adjusting the rest of the controls breath by breath.
high flow O2 therapy is available to support patients requiring increased oxygen levels.
All screen layouts are customizable to suit the specific needs of patients and clinicians.
User interface can be used in light and dark both themes as per preference of the clinician or comfort of the patient.
4 different fully customizable presets, which can store preferences for settings, user interface and defaults, can be stored as per clinical conditions or multiple clinician’s preferences, working in same place.
VENSI provides on screen guidance on all parameters, maneuvers, controls, modes and settings, just on a click.
VENSI provides on screen guidance for all critical events, so that the basic troubleshooting can be done on spot without any external help.
Vensi's smart safety features show alarms priority wise, and also adjust the alarm levels dynamically with change of parameters on the go. Smart safety feature changes the range of controls automatic ally as per patient type and IBW and other parameters, to alerts doctors and avoid any incorrect parameter settings, minimizing the risk of errors.
Option | Availability |
---|---|
SpO2 Port | |
EtCO2 Port | |
DC Input | |
Cuff Monitoring | + |
Wifi connectivity | |
Nurse call Systems | |
Neonatal Ventilation | |
Dual Battery Systems | |
Humidifier Integration | + |
Paramagnetic O2 Sensor | + |
Auxiliary Pressure monitoring | + |
External Display connectivity |
Option | Availability |
---|---|
Dark-Light Theme | |
Non-Invasive Ventilation | |
Neonatal Ventilation & NCPAP | |
High Flow O2 Therapy | |
Smart Ventilation | |
Smart-Lung | |
PV Tool | |
Onscreen Help | |
DualPAP & APRV | |
PRVC & PRVC-SIMV | |
VS & PSV-ST | |
ATRC & Intellicycle | |
Weaning & NIF | |
PEEPi & P0.1 | |
SI & Alv Vent Calculation | |
Multi Presets | |
Loops & Trends | |
Remote & Central Monitoring | |
Swipe & screen Customisation |
Option | Availability |
---|---|
SpO2 Port | |
EtCO2 Port | |
DC Input | |
Cuff Monitoring | - |
Wifi connectivity | |
Nurse call Systems | |
Neonatal Ventilation | + |
Dual Battery Systems | |
Humidifier Integration | + |
Paramagnetic O2 Sensor | + |
Auxiliary Pressure monitoring | - |
External Display connectivity | - |
Option | Availability |
---|---|
Dark-Light Theme | |
Non-Invasive Ventilation | |
Neonatal Ventilation & NCPAP | + |
High Flow O2 Therapy | |
Smart Ventilation | |
Smart-Lung | |
PV Tool | + |
Onscreen Help | - |
DualPAP & APRV | |
PRVC & PRVC-SIMV | |
VS & PSV-ST | |
ATRC & Intellicycle | |
Weaning & NIF | + |
PEEPi & P0.1 | + |
SI & Alv Vent Calculation | + |
Multi Presets | + |
Loops & Trends | |
Remote & Central Monitoring | + |
Swipe & screen Customisation |
Option | Availability |
---|---|
SpO2 Port | + |
EtCO2 Port | + |
DC Input | + |
Cuff Monitoring | - |
Wifi connectivity | + |
Nurse call Systems | + |
Neonatal Ventilation | |
Dual Battery Systems | + |
Humidifier Integration | + |
Paramagnetic O2 Sensor | - |
Auxiliary Pressure monitoring | - |
External Display connectivity | + |
Option | Availability |
---|---|
Dark-Light Theme | |
Non-Invasive Ventilation | + |
Neonatal Ventilation & NCPAP | |
High Flow O2 Therapy | |
Smart Ventilation | - |
Smart-Lung | - |
PV Tool | - |
Onscreen Help | + |
DualPAP & APRV | + |
PRVC & PRVC-SIMV | + |
VS & PSV-ST | - |
ATRC & Intellicycle | - |
Weaning & NIF | + |
PEEPi & P0.1 | + |
SI & Alv Vent Calculation | + |
Multi Presets | |
Loops & Trends | + |
Remote & Central Monitoring | + |
Swipe & screen Customisation |
Option | Availability |
---|---|
SpO2 Port | - |
EtCO2 Port | - |
DC Input | - |
Cuff Monitoring | - |
Wifi connectivity | - |
Nurse call Systems | - |
Neonatal Ventilation | - |
Dual Battery Systems | - |
Humidifier Integration | - |
Paramagnetic O2 Sensor | - |
Auxiliary Pressure monitoring | - |
External Display connectivity | - |
Option | Availability |
---|---|
Dark-Light Theme | |
Non-Invasive Ventilation | + |
Neonatal Ventilation & NCPAP | - |
High Flow O2 Therapy | + |
Smart Ventilation | + |
Smart-Lung | + |
PV Tool | + |
Onscreen Help | - |
DualPAP & APRV | + |
PRVC & PRVC-SIMV | + |
VS & PSV-ST | + |
ATRC & Intellicycle | + |
Weaning & NIF | + |
PEEPi & P0.1 | + |
SI & Alv Vent Calculation | + |
Multi Presets | - |
Loops & Trends | + |
Remote & Central Monitoring | - |
Swipe & screen Customisation | + |
Physical Specifications |
|
Dimension: | 1395mmx 530mmx 674mm with trolley 651mmx 401mmx 298mm excluding trolley |
Weight: | Approximately 45 Kg (including trolley) Approximately 25 Kg (excluding trolley) |
Screen: | 15.6" Color TFT Touch Screen |
Resolution: | 1920x1020 Pixels |
Brightness: | Adjustable |
Ventilation |
|
Patient Type: | Adult/Paediatric/Neonatal |
Ventilation Modes: | VA/C (Volume assist/control), P-A/C (Pressure assist/control), V-SIMV (Volume-synchronised intermittent mandatory ventilation). P-SIMV (Pressure-synchronised intermittent mandatory ventilation), Duo-Level (Duo level ventilation). CPAP(continuous positive airway pressure). PSV (Pressure Support Ventilation), VS (Volume support). APRV (Airway pressure release ventilation),PRVC (Pressure regulated volume controlled ventilation),PRVC-SIMV, AMV (Adaptive minute ventilation). PSV-ST (Pressure support ventilation spontaneous-timed). nCPAP (nasal CPAP) NIV (Non invasive ventilation). Apnea Ventilation |
Alarms |
|
Audio And Visual Alarms |
|
Volume: | Tidal Volume (Low/High), Minute Volume (Low/High) |
Pressure: | Airway Pressure (Low/High), PEEP Too High, Pressure Limitation, |
Others: | Frequency (Low/High). Inspired Oxygen (FiO2) (Low/High), Apnea Alarm Time (Low, 5-60s), Airway Obstruction, Tube Disconnected, 02 Supply Pressure High/Low/ Fail, Apnea, Apnea Backup, Freq High/Low, Expiatory Block, Gas Supply Pressure Low |
Power: | Low Battery Voltage, AC Power Fail |
Apnea Ventilation |
|
Papnea: | 1 to 100 cmH20 |
Tvapnea: Adult: | 100 to 4000 mL Paediatric: 20 to 300 mL. Neonatal: 2 to 100 mL |
Apnea Tinsp: | 0.10 to 10.00 s |
f(Respiratory rate): | Adult/Paediatric: 1 to 100/min Neonatal: 1 to 150/min |
Sigh |
|
Sigh Switch: | ON,OFF |
Interval: | 20s to 180min |
Cycles Sigh: | 1 to 20 |
Int, PEEP: | OFF, 1to 40 cmH2O |
Automatic Tube Resistance Compliance |
|
Tube Type: | ET tube, Trach Tube, Disable ATRC |
Tube I.D.: | Adult: 5.0 to 12. Mm Paediatric: 2.5 to 8.00 mm Neonatal: 2.5 to 5.0 mm |
Compensate: | 1 to 100% |
Expiration Compliance Switch: | ON, OFF |
O2 Therapy |
|
O2%: | 21-100 vol% |
Flow: | Adult: 65LPM Paediatric: 2 to 25 LPM |
Leakage Compensation |
|
Maximum: | Adult: 65 LPM |
Leakage: | Paediatric: 45 LPM |
Compensation Flow: | Neonatal: 15 LPM |
Data Storage |
|
Trends |
|
Type: | Tabular, Graphics |
Length: | 120 hours |
Content: | Monitor para, Settings Para, Setting ventilation mode and parameter |
Log |
|
Type: | Alarm, Operation |
Max Number: | 5000 |
Screen Capture |
|
Max Number: | 20 pictures |
Environment |
|
Temperature: | 10 to 40°C |
Relative Humidity: | 10 to 95% |
Barometric Pressure: | 50 to 106 kPa |
Air Supply |
|
Maximum Output Flow: | 200 L/min (BTPS)* |
Maximum Output Pressure: | 80 cmH20 |
Power & Battery Backup |
|
Power Input Voltage: | 10 to 40°C |
Power Input Frequency: | 50/60 Hz |
Power Input Current: | 2.8 to 1.2 A |
Fuse: | 220V/5.0A |
Number Of Batteries: | One or Two |
Battery Type: | Build-in Lithium-ion battery. 11.3 VDC, 5600 mAh |
Battery Run Time: | 90 min (Powered by one new fully-charged battery in standard working condition)" 180 min (Powered by two new fully-charged battery in standard working condition) |
Special Functions |
|
Special Functions: | 100% O2 Suction, Nebulization, Manual Breath, Inspiratory Hold, Expiratory Hold. PEEPI, PO.1, NIF, PV-Tool, Weaning Tool, Lung Recruitment Tool (SI), Alveolus Ventilation Calculation |
Monitoring Parameter |
|
Airway Pressure: | Ppeak, Pplat, Pmean -20 to 120 cmH20 PEEP (0 to 120 cmH20) |
Tidal Volume: | Tvi, Tve, Tve-spn (0 to 6000mL) |
Frequency Range: | ftotal, fmand, fspn (0 to 200/min) |
Minute Volume: | MVI, MVe, MVleak, MVspn. Adult/paediatric: 0 to 100 LPM Neonatal: 0 to 30 LPM |
Resistance: | Rinsp, Rexp(0 to 600 cmH20/L/s) |
Compliance: | Cstat, Cdyn (0 to 300 mL/cmH2O) |
Inspired 02 (FI02): | 15 to 100 vol.% |
RSBI: | 0 to 9999 1/(min"L) |
WOB: | WOBtot, WOBvent, WOBimp,WOBpat (0 to 100 J/min) |
P0.1: | -20 to 0 cmH20 |
NIF: | -45 to 0 cmH20 |
PEEPI: | 0 to 120 cmH2O |
Vtrap: | 0 to 4000mL |
RCexp: | O to 10s |
TVe/IBW: | 0 to 50 mL/kg |
I:E: | 150:1 to 1:150 |
Tinsp: | 0.00 to 60.00s |
PIF (Peak Inspiratory Flow): | Adult/Paediatric: 0 to 300 LPM, Neonate: 0 to 30 LPM |
PEF (Peak Expiratory Flow): | Adult/Paediatric: 0 to 180 LPM, Neonate: 0 to 30 LPM |
EEF (End Expiratory Flow): | Adult/Paediatric: 0 to 180 LPM, Neonate: 0 to 30 LPM |
C20/C: | 0.00 to 5.00 |
Waveforms: | Airway Pressure-Time, Flow-Time, Volume-Time, CO2-Time, Pleth-Time |
Loops: | Paw-Volume, Flow-Volume, Paw-Flow, Volume-CO2 |
Control Parameter |
|
02%: | 21-100 vol% |
Tv (Tidal Volume): | Adult: 100 to 4000 mL, Paediatric: 20 to 300 mL, Neonatal: 2 to 100 mL |
MV%: | 25% to 350% |
f(Respiratory rate): | Adult/Paediatric: 1 to 100/min, Neonatal: 1 to 150/min |
f-SIMV: | 1 to 60 /min |
IE: | 1:10 to 4:1 |
Ti (Inspiratory Time): | 0.10 to 10.00's |
Tslope (Pressure Rise Time): | 0.00 to 2.00s |
Thigh: | 0.10 to 30.00s |
Tlow: | 0.20 to 30.00 s |
Tpause: | Off, 5% to 60% |
Pinsp: | 1 to 100 cmH20 |
Psupp: | 0 to 100 cmH20 |
Phigh: | 0 to 100 cmH20 |
Plow: | 0 to 50 cmH20 |
PEEP: | 0 to 50 cmH20 |
Flow Trigger: | Off. Adult/Paediatric: 0.5 to 30 LPM Neonate: 0.1 to 5.0 LPM |
Pressure Trigger: | Off, -20.00 to -0.5 cmH20 |
Exp%: | Auto, 5% to 85% |
Ensuring Patient’s safety and Doctor's Ease of Use
Set the desired minute volume support percentage, and VENSI handles the rest of the adjustments breath by breath.
Graphical lung parameter representation enabling quick assessment for optimized respiratory care.
Advanced tools like PV tool, Vt/IBW, C20/C, and lung recruitment enhance lung protection through small tidal volume ventilation, PEEP titration, and recruitment.
Automatic range adjustment based on patient type and IBW alerts doctors, avoiding any incorrect parameter settings and minimizing the risk of errors
Introducing a revolutionary solution that aligns with the latest international standards, including ISO 80601-2-12 and ISO 80601-2-55, as well as the updated CE guideline. This guideline emphasizes the importance of detachable valves (both inspiratory and expiratory) capable of withstanding high-temperature sterilization, thereby minimizing the risk of cross-contamination.
The Breathing Cassette incorporates an advanced sterilization monitoring system that ensures rigorous infection control. This feature verifies proper sterilization after each use, guaranteeing patient safety and minimizing the risk of cross-contamination.
The Breathing Cassette simplifies respiratory care with its integrated inspiratory and expiratory valves. This design not only streamlines the ventilation but also makes operation hassle free.
Inside the Breathing Cassette lies an integrated reusable flow sensor. This sophisticated sensor provides accurate monitoring of respiratory parameters, allowing for precise and customized patient care while reducing the need for frequent replacements.
The Breathing Cassette is equipped with an integrated eUV filter, harnessing the power of ultraviolet (UV) technology to purify the air. This innovative feature ensures that the exhaled air released by patient is clean and free from harmful pathogens, enhancing overall infection control in ICU.
Designed for user convenience, the Breathing Cassette features a single-button removal mechanism. This user-friendly design simplifies the equipment's maintenance, optimizing healthcare professionals' workflow and ensuring efficient care delivery.
Get in touch with us using our contact form.