Common sterlization protocols and mistakes

Beyond the Machine: A Deep Dive into Ventilator Sterilization

Date: November 29, 2023 | Posted by: Vikram Aditya Tirthani

Neglecting Proper Sterilisation in Ventilators

In the intricate world of ventilator management, the spotlight often shines on the main components, but what about the unsung heroes—the accessories that accompany them? Neglecting the sterilization of these crucial elements can give rise to a myriad of issues, jeopardizing both patient safety and the well-being of those within the ICU. Let’s unravel the unseen dangers of neglecting proper sterilization in ventilators.

  1. Risk of Infection:

The foremost peril of overlooking sterilization is the proliferation of infections. Ventilators, in direct contact with a patient’s respiratory system, become breeding grounds for harmful microorganisms if not cleaned correctly. This oversight can result in the transmission of infections from one patient to another, posing a severe threat to vulnerable individuals.

  1. Spread of Antibiotic-Resistant Bacteria:

Improperly sterilized ventilators contribute to the spread of antibiotic-resistant bacteria, a growing concern in healthcare settings. Superbugs, difficult to treat and potentially lethal, thrive when sterilization protocols are not diligently followed. Patients reliant on ventilator support with weakened immune systems become more susceptible to infections, complicating their conditions and extending hospital stays.

One common type of infection that can occur due to improper sterilisation is healthcare-associated pneumonia (HAP). This condition develops when bacteria from unsterilized ventilator parts enter a patient’s lungs through the breathing tubes. HAP can be difficult to treat and may lead to serious complications or even death.

Another potentially life-threatening infection that can arise from inadequate sterilisation is bloodstream infection (BSI). BSI occurs when bacteria or other harmful microorganisms enter a patient’s bloodstream through contaminated ventilator components. This type of infection is particularly dangerous as it can spread quickly throughout the body and cause sepsis, a severe inflammatory response that can be fatal if left untreated.

  1. Cross-Contamination:

Ventilators often serve multiple patients throughout their lifespan, elevating the risk of cross-contamination if not thoroughly sanitized between uses. Parts from one patient’s ventilator coming into contact with another’s respiratory system can lead to life-threatening infections, underscoring the critical need for meticulous sterilization practices.

  1. Malfunctioning Equipment:

Neglecting ventilator sterilization can compromise the machine’s effectiveness in delivering oxygen. Accumulated dust, dirt, and debris on vital components may impede performance, potentially resulting in inadequate oxygen delivery or equipment malfunction. This scenario puts patients relying on ventilators at substantial risk.

Common Mistakes in Sterilizing Ventilator Accessories

  1. Not Following Manufacturer’s Instructions:

A prevalent mistake is neglecting the specific sterilization instructions provided by the manufacturer. Different accessories may require distinct cleaning and disinfection methods, emphasizing the importance of adhering to guidelines to ensure effective sterilization and minimize contamination risks.

  1. Improper Cleaning Before Sterilization:

Sterilization cannot be effective without proper cleaning. Skipping or inadequately performing this step may compromise the entire process. Gentle cleaners recommended by the manufacturer should be used, and all debris and residue must be removed before proceeding with sterilization.

  1. Using Expired or Ineffective Disinfectants:

The use of expired or inappropriate disinfectants can compromise the sterility of ventilator accessories. Regularly checking expiration dates and ensuring the efficacy of the disinfectant against specific microorganisms are crucial steps in maintaining a sterile environment.

Common Sterilization Methods

Cleaning Methods:

Wipe: wipe with a damp cloth immersed in alkalescent detergent (soapy water, etc.) or alcohol solution, and then wipe off the remaining detergent with a dry lint-free cloth.

Immersion: flush with water first and then immerse it in alkalescent detergent (soapy water, etc., water temperature of 40ºC recommended) for approximately three minutes. Finally, clean with water and dry completely.

Methods for Disinfection:

A: Wipe: wipe with a damp cloth immersed in medium- or high-efficiency detergent and then wipe off the remaining detergent with a dry lint free cloth.

B: Immersion: immerse it in medium- or high-efficiency detergent for more than 30 minutes (recommended time). Then clean with water and dry completely.

C: Steam autoclave at 134ºC for 15 minutes (recommended time)

D: Ultraviolet radiation for 30 to 60 minutes (recommended time).

The table below lists the cleaning and disinfecting agents and autoclaving process that may be used on the ventilator.

Ethanol (75%) Moderately efficient disinfectant
 

Isopropanol (70%)

 

Moderately efficient disinfectant

 

Glutaraldehyde (2%)

 

Highly efficient disinfectant

 

Ortho-Phthalaldehyde disinfectant (such as Cidex®OPA)

Highly efficient disinfectant
 

Soap water (pH value of 7.0~10.5)

 

Rinsing agent

 

Clean water

 

Rinsing agent

 

Steam autoclave at the recommended temperature of this disinfection method is 134ºC (273ºF).

Highly efficient disinfection

 

Part-Wise Recommendations for Sterilization

  • Ventilator Exterior:
    • Common Parts: Housing, Gas supply hose, Power cables, O2 cylinder holding system, Trolley, Mounting systems, Handles, Supporting arm
    • Frequency: After each patient
    • Cleaning Method: Wipe
    • Disinfection Method: Wipe or ultraviolet radiation
  • HMI (Human-Machine Interface):
    • Common Parts: Display and touch screens
    • Frequency: After each patient
    • Cleaning Method: Wipe
    • Disinfection Method: Wipe or ultraviolet radiation
  • Filters:
    • Common Parts: Air intake dust filter, Fan dust filter, Main unit air outlet dust filter
    • Frequency: Every 4 weeks
    • Cleaning Method: Immersion
    • Disinfection Method: Immersion
  • Breathing Circuit Components:
    • Common Parts: Inspiratory safety valve cover, All silicon membranes and flaps, Inspiratory port and Expiratory port, Expiratory cover/cassette, and other components
    • Frequency: After each patient or weekly
    • Cleaning Method: Immersion
    • Disinfection Method: Autoclave
  • Reusable Accessories and Modules:
    • Common Parts: Patient tubing, Nebulizers, Masks, Water traps
    • Frequency: After each patient or weekly
    • Cleaning Method: Immersion
    • Disinfection Method: Autoclave

 

Proper sterilization of ventilator accessories is paramount to ensuring patient safety and the optimal functioning of life-saving devices. By avoiding common mistakes and following recommended sterilization methods, healthcare facilities can mitigate the risks associated with infections, cross-contamination, and equipment malfunction. A vigilant approach to sterilization safeguards both patients and healthcare professionals, underscoring the critical role of meticulous care in ventilator management.